Design
Engineering
Analysis
Pipe
Survey & Analysis
Cured
in Place Pipe
(CIPP)
Fold
& Form Pipe
(F&FP)
Pipe
Bursting
and
Slip Lining
Manhole
Restoration |
|
 |
|

DESCRIPTION
|
Manhole Restoration(Renewal) is a process for structurally
reinforcing and sealing leaky and deteriorated manholes by centrifugal
casting a design formulated mortar liner onto the interior walls of
existing manhole structures using a non-entry high-speed, rotating
device. The renewal process features an ultra high strength, corrosion
resistant mortar based on Micro Silica and Portland Cement combined
with protection against MIC (Microbiologically Induced Corrosion).1
| MORTAR
TECHNICAL DATA |
| Compressive
Strength |
ASTM
D-695 |
16,800
psi |
| Flexural
Strength |
ASTM
D-790 |
13,900
psi |
| Tensile
Strength |
ASTM
D-638 |
12,400
psi |
| Hardness |
ASTM
D-2240 |
68-72
Shore D |
| Impact
Resistance |
NCS-PS55 |
160
in. lbs |
| Heat
Resistance |
ASTM
D-648 |
220
¼F |
| Ultimate
Elongation |
ASTM
D-638 |
4.5% |
| Adhesive
Shear |
ASTM
C-882 |
1000psi |
| Mixing
Ratio |
1:1 |
| Working
Pot Life |
40
min @ 75¼F |
| Viscosity |
Same
as thick paint-18,000 cps @ 75¼F |
| Dry
time |
4-6
hours @ 75¼F |
| Recoat |
6-24
hours |
| CHARACTERISTICS |
|
| Coverage |
25
sq.ft/gal. @ .065 thickness |
| Number
of coats |
One |
| Color |
White |
| Finish |
Glossy |
| Clean
up |
Xylol,
Touluol or Lacquer thinner |
| Weight |
11.5
lbs./mixed gallon |
| MIC
PROTECTION PROPERTIES |
| Unit
Weight |
125pcf |
| Color |
Light
Gray |
| Special
handling |
None-Keep
dry |
| Shelf
Life |
One
year |
| Water
Demand |
Water/cement
ratio 0.40 |
| Coverage |
50#bag
yields 0.40 cf |
| Working
Time |
40
minutes |
| Set
Time at 70¼F ASTM C-403 |
| Initial
Set |
244
minutes |
| Final
Set |
440
minutes |
| Modulus
of Elasticity ASTM C-469 |
| 24
hours |
180,000
psi |
| 28
days |
1,150,000
psi |
| Flexural
Strength ASTM C-293 |
| 24
hours |
650
psi |
| 28
days |
800
psi |
| Compressive
Strength ASTM C-109 |
| 24
hours |
3,000
psi |
| 28
days |
10,000
psi |
| Tensile
Strength |
600
psi |
| Shrinkage |
None |
| Chloride
Permeability |
<550
coulombs |
1Specifications and methods for manhole renewal may vary
based on manufactures specification. |
For
suggestions, comments, and concerns about this page,
e-mail us at: webmaster@afcotech.com
Date of last update: December
1 , 2000
© 2000
AFCO Technologies, Inc.
|